Settings - 3rd Party Software
With this part of the program you can start any application and if needed close it when a selected temperature sensor has reached selected sensors.
Use the + and - buttons to add and remove a program to the list. You can have 10 programs in the list.
Enabled
Enable all settings for the selected program
Temperature sensor to which this program should be linked
Select the MBM 5 sensor to which the select program should be linked.
Temperature at which this program should be started
Here you select the start temperature, it is allowed to have the start temperature lower then the stop temperature, in case you need to start something to head the CPU temperature up
Temperature at which this program should be closed
Here you select the stop temperature, it is allowed to have the stop temperature higher then the start temperature, in case you need to stop something after it heated the CPU temperature
Start application with switch (%value% will place the value of the sensor on its location)
You can start the program you selected with a switch if needed. A special option is to use %value% just like this, so no caps. MBM 5 will replace %value% with the temperature of the selected sensor. So say the temperature is 50c, then filling in switch1 %value% switch3 will start the programm with the switches switch1 50 switch2
Check program is still running after it has been started; if not, then start it again
If you check this then MBM 5 will check up on the program it started. If the user closed this program then MBM 5 will start it again. This should not be used if the program you start with MBM 5 will stop by itself, else MBM 5 will start it again and again and again
Let MBM close the program it started when MBM itself is closed
That's what it does, if you close MBM 5 it will close the selected program if MBM 5 started it and it's still running